Vista de pagina 48
Control menu 49

(Press
and hold
Enter for a
few
seconds
to use this
menu)


Enable pan/tilt position correction system.

Disable pan/tilt feedback. Setting not saved.


Enable on the fly reset of color, gobo, and effect wheels.

Disable on the fly reset of color, gobo, and effect wheels.

See “Adjustment submenu” on page 50.
 
Pan offset.
 
Tilt offset.
 
Dimmer offset.
 
Cyan offset.
 
Magenta offset.
 
Yellow offset.
 
CTC offset.
 
Gobo wheel offset.
 
Effect wheel offset.
 
Iris offset.
 
Focus offset.
 
Zoom offset.
 
Return all offsets to the default settings.
 
PCB test for service use only.


Regulate the effect cooling fans for quieter performance. Enabling
this option increases the operating temperature and thus increases
wear on the components.

Operate cooling fans at full speed. This is the default from software
version 1.4.
 
Manually set fixture to software update mode.

(when
Service
LED is lit)

Displayed when lamp hours exceed average life (750 hours).

Displayed if head temperature exceeds 120° C (248° F).
Menu Item Options Notes (Default settings in bold print)
Table 2: Control menu